Abstract
Total hip arthroplasty (THA) has been regarded as one of the major orthopedic surgeries used to restore the normal functionality of the joint, as well as relieve pain in cases of degenerative hip diseases. Although it has a high clinical success rate, stress shielding, loosening of implant, wear, and periprosthetic fracture remain complicating factors reducing the survival of the implant in the long-term. Over the past decades, the finite element analysis (FEA) has become an effective computational method to assess the biomechanical characteristics of hip implants and design them in the most optimal way before using them in clinical practice. This review gives a detailed description of how FEA is used in total hip arthroplasty, optimal implant geometry, biomaterial choice, porous and lattice structures and biomechanical performance assessment. Moreover, the development of patient-specific modelling, additive manufacturing, and optimization of the design with the help of artificial intelligence is addressed. Lastly, research gaps and future opinions are presented that will help in the research of the next generation of hip implants that would have better clinical reliability and mechanical compatibility in the long run.
References
D. Learmonth, C. Young, and C. Rorabeck, “The operation of the century: Total hip replacement,” The Lancet, vol. 370, pp. 1508–1519, 2007, doi.org/10.1016/S0140-
6736(07)60457-7
G. Bergmann, G. Deuretzbacher, M. Heller, F. Graichen, A. Rohlmann, J. Strauss, and G. N. Duda, “Hip contact forces and gait patterns from routine activities,” Journal of Biomechanics, vol. 34, pp. 859–871, 2001, doi.org/10.1016/S0021-9290(01)00040-9
S. M. Kurtz, K. L. Ong, E. Lau, F. Mowat, and M. Halpern, “Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030,” Journal of Bone and Joint Surgery, vol. 89, pp. 780–785, 2007, doi.org/10.2106/JBJS.F.00222
R. Huiskes, H. Weinans, and B. van Rietbergen, “The relationship between stress shielding and bone resorption around total hip stems,” Journal of Biomechanics, vol. 25, pp. 1241–1251, 1992, doi.org/10.1016/0021-9290(92)90280-B
M. Taylor and P. J. Prendergast, “Four decades of finite element analysis of orthopaedic devices,” Journal of Biomechanics, vol. 48, pp. 767–778, 2015, doi.org/10.1016/j.jbiomech.2014.12.034
M. Viceconti, F. Baleani, E. Squarzoni, and A. Toni, “The role of finite element analysis in orthopaedic biomechanics,” Journal of Biomechanics, vol. 34, pp. 1079–1087, 2001, doi.org/10.1016/S0021-9290(01)00039-2
N. Taniguchi et al., “Effect of pore size on bone ingrowth into porous titanium implants,” Acta Biomaterialia, vol. 44, pp. 129–138, 2016, doi.org/10.1016/j.actbio.2016.08.009
A. A. Zadpoor, “Mechanical performance of additively manufactured meta-biomaterials,” Acta Biomaterialia, vol. 85, pp. 41–59, 2019, doi.org/10.1016/j.actbio.2018.12.038
M. Niinomi, “Mechanical biocompatibilities of titanium alloys for biomedical applications,” Materials Science and Engineering C, vol. 28, pp. 992–1000, 2008, doi.org/10.1016/j.msec.2007.06.044
S. M. Kurtz, “UHMWPE biomaterials handbook: Ultra-high molecular weight polyethylene in total joint replacement,” Elsevier, 2016, doi.org/10.1016/C2013-0-19027-2
C. Piconi and G. Maccauro, “Zirconia as a ceramic biomaterial,” Biomaterials, vol. 20, pp. 1–25, 1999, doi.org/10.1016/S0142-9612(98)00010-6
J. D. Currey, Bones: Structure and Mechanics, Princeton University Press, 2002, doi.org/10.1515/9781400849505
J. Black and G. Hastings, Handbook of Biomaterial Properties, Springer, 2013, doi.org/10.1007/978-1-4757-1147-5
O. Harrysson, D. Marcellin-Little, and K. Hornberger, “Direct metal fabrication of orthopedic implants,” Materials Science and Engineering C, vol. 28, pp. 366–373, 2008, doi.org/10.1016/j.msec.2007.04.022
H. Weinans, R. Huiskes, and H. J. Grootenboer, “The behavior of adaptive bone remodeling simulation models,” Journal of Biomechanics, vol. 25, pp. 1425–1441, 1993, doi.org/10.1016/0021-9290(93)90056-7
J. Y. Rho, L. Kuhn-Spearing, and P. Zioupos, “Mechanical properties and hierarchical structure of bone,” Medical Engineering & Physics, vol. 20, pp. 92–102, 1998, doi.org/10.1016/S1350-4533(98)00007-1
M. Taddei et al., “Finite element modeling of bones from CT data: Sensitivity to material properties and mesh density,” Journal of Biomechanics, vol. 37, pp. 1471–1480, 2004, doi.org/10.1016/j.jbiomech.2003.12.020
S. V. Dorozhkin, “Calcium orthophosphate coatings on biomedical implants,” Surface and Coatings Technology, vol. 201, pp. 156–173, 2007, doi.org/10.1016/j.surfcoat.2006.08.120
T. Lerch et al., “Metaphyseal anchoring short stems in total hip arthroplasty,” Journal of Orthopaedic Surgery and Research, vol. 15, 2020, doi.org/10.1186/s13018-020-02027-4
M. Ceddia et al., “Influence of femoral stem material on stress shielding,” Journal of Composites Science, vol. 8, 2024, doi.org/10.3390/jcs8070254
A. A. Zadpoor, “Mechanical performance of additively manufactured meta-biomaterials,”
Acta Biomaterialia, vol. 85, pp. 41–59, 2019, doi.org/10.1016/j.actbio.2018.12.038
M. Viceconti, F. Baleani, E. Squarzoni, and A. Toni, “The role of finite element analysis in orthopaedic biomechanics,” Journal of Biomechanics, vol. 34, pp. 1079–1087, 2001, doi.org/10.1016/S0021-9290(01)00039-2
S. Affatato, “Wear behaviour of ceramic-on-ceramic hip prostheses,” Materials & Design, vol. 110, pp. 365–372, 2016, doi.org/10.1016/j.matdes.2016.07.060
J. J. Jacobs, T. L. Paprosky, and C. J. Della Valle, “Biomedical engineering approaches in hip replacement,” Journal of Biomechanics, vol. 45, pp. 987–993, 2012, doi.org/10.1016/j.jbiomech.2012.01.005
M. Taylor, “Finite element analysis of the resurfaced femoral head,” Medical Engineering & Physics, vol. 28, pp. 859–865, 2006, doi.org/10.1016/j.medengphy.2005.12.003
A. Bahraminasab and M. J. Sahari, “Finite element investigation of the influence of implant material on stress distribution,” Materials & Design, vol. 44, pp. 155–163, 2013, doi.org/10.1016/j.matdes.2012.07.045
M. Niinomi and M. Nakai, “Titanium-based biomaterials for orthopedic applications,” Acta Biomaterialia, vol. 7, pp. 3422–3434, 2011, doi.org/10.1016/j.actbio.2011.06.034
P. J. Prendergast, “Finite element models in tissue mechanics and orthopaedic implant design,” Clinical Biomechanics, vol. 12, pp. 343–366, 1997, doi.org/10.1016/S0268-
0033(97)00053-1
R. Huiskes and H. Weinans, “Adaptive bone remodeling theory applied to prosthetic design,” Journal of Biomechanics, vol. 25, pp. 1425–1441, 1992, doi.org/10.1016/0021-9290(92)90280-B
C. H. Turner and D. B. Burr, “Basic biomechanical measurements of bone: A tutorial,” Bone, vol. 14, pp. 595–608, 1993, doi.org/10.1016/8756-3282(93)90081-K
S. M. Kurtz and J. N. Devine, “PEEK biomaterials in trauma, orthopedic, and spinal implants,” Biomaterials, vol. 28, pp. 4845–4869, 2007, doi.org/10.1016/j.biomaterials.2007.07.013
L. Yang, J. Sheldon, and A. Webster, “Porous titanium structures for orthopedic implants,”
Acta Biomaterialia, vol. 83, pp. 29–45, 2019, doi.org/10.1016/j.actbio.2018.10.040
S. Bose, D. Ke, H. Sahasrabudhe, and A. Bandyopadhyay, “Additive manufacturing of biomaterials,” Progress in Materials Science, vol. 93, pp. 45–111, 2018, doi.org/10.1016/j.pmatsci.2017.08.003
J. A. Helsen and H. J. Breme, Metals as Biomaterials, Wiley, 1998, doi.org/10.1002/9783527612796
J. D. Bobyn, M. Tanzer, J. J. Krygier, J. O. Dujovne, and S. M. Brooks, “The effect of porous coating on implant fixation,” Clinical Orthopaedics and Related Research, vol. 298, pp. 291–300, 1994, doi.org/10.1097/00003086-199401000-00036
A. Arabnejad Khanoki and D. Pasini, “Multiscale design and optimization of orthopedic implants,” Acta Biomaterialia, vol. 8, pp. 3442–3451, 2012, doi.org/10.1016/j.actbio.2012.05.028
H. Van der Meulen and R. Huiskes, “Why mechanobiology?” Journal of Biomechanics, vol. 35, pp. 401–414, 2002, doi.org/10.1016/S0021-9290(01)00221-4
S. H. Rho, L. Kuhn-Spearing, and P. Zioupos, “Mechanical properties and hierarchical structure of bone,” Medical Engineering & Physics, vol. 20, pp. 92–102, 1998, doi.org/10.1016/S1350-4533(98)00007-1
P. J. Prendergast, R. Huiskes, and K. Søballe, “Biomechanical considerations in implant fixation,” Journal of Biomechanics, vol. 30, pp. 539–548, 1997, doi.org/10.1016/S0021-9290(96)00199-3
M. Taylor and M. Browne, “Finite element modelling of orthopaedic implants,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 1, pp. 1–12, 2008, doi.org/10.1016/j.jmbbm.2007.05.001
D. Taylor, “Biomechanics of hip implants,” Medical Engineering & Physics, vol. 19, pp. 639–646, 1997, doi.org/10.1016/S1350-4533(97)00019-6
A. A. Zadpoor and J. Malda, “Additive manufacturing of biomaterials and tissue engineering scaffolds,” Biomaterials, vol. 85, pp. 1–7, 2017, doi.org/10.1016/j.biomaterials.2016.12.026
B. Derby, “Additive manufacture of ceramics components,” Annual Review of Materials Research, vol. 40, pp. 395–414, 2010, doi.org/10.1146/annurev-matsci-070909-104433
M. M. Rahman, A. H. Kadirgama, and M. Noor, “Finite element analysis of hip joint prosthesis,” Computer Methods in Biomechanics and Biomedical Engineering, vol. 19, pp. 1155–1163, 2016, doi.org/10.1080/10255842.2015.1093451
J. Hazlehurst, C. Wang, and M. Stanford, “The use of additive manufacturing in orthopedic implants,” Materials & Design, vol. 35, pp. 726–730, 2012, doi.org/10.1016/j.matdes.2011.09.040
S. Bagherifard et al., “Surface modification of orthopedic implants,” Acta Biomaterialia, vol. 79, pp. 124–137, 2018, doi.org/10.1016/j.actbio.2018.08.041
J. M. Mirzaali and A. A. Zadpoor, “Mechanical behavior of lattice biomaterials,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 98, pp. 447–459, 2019, doi.org/10.1016/j.jmbbm.2019.06.019
T. D. Brown, M. T. Pedersen, and D. R. Callaghan, “Finite element modeling of bone remodeling around implants,” Journal of Biomechanics, vol. 35, pp. 147–156, 2002, doi.org/10.1016/S0021-9290(01)00163-3
G. Harrysson, O. Cansizoglu, and D. Marcellin-Little, “Direct metal fabrication of orthopedic implants,” Materials Science and Engneering C, vol. 28, pp. 366–373, 2008, doi.org/10.1016/j.msec.2007.04.022
A. Simoneau, P. Terriault, and V. Brailovski, “Mechanical behavior of porous titanium implants,” Biomedical Materials, vol. 12, 2017, doi.org/10.1088/1748-605X/aa5a0c

This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c) 2026 Berisso Woyessa Bekele (Author)